Pittsburgh Homes for Sale Baldwin Homes for Sale 460 Macassar Dr Pittsburgh, PA 15236 $269,900 Just Listed For Sale Active Single Family 3 Beds 2 Full Baths Updated 29 minutes ago Next open house: Saturday 4/29 11:00 AM - 1:00 PM Get directions 25 Photos Map & Location Street View Huge Savings New Hot Tub Spa Sale Check it out today.Over 120 models throughout the six locations and warehouse ready to be delivered to your home in time for the holidays. The Spa Sale every yinzer has been waiting for, the Pittsburgh Super Spa Sale is happening this weekend! All 2019 hot tub floor models are at clearance pricing to make room for the new 2020 models due in any month now. Hydrotherapy is a therapeutic whole-body treatment that involves moving and exercising. A jet system creates a smooth current of water ideal for fitness activities, and massage jets offer relief from stress, aches, and muscle pain. This then pairs with a bigger pump which is in charge of fueling the spas jets. Service areas: Pittsburgh and surrounding areas, including Clarion, Hermitage, DuBois, Cranberry Township and Robinson. The company’s hot tub trade-in program has a minimum return of $500.Creating The Perfect Space for Your Indoor Hot Tub Best Hot Tub Strength Training Exercises for Fat Loss ThermoSpas Smallest Hot Tubs.Whether you live in downtown Philly, on a farm in central PA, or on the outskirts of Pittsburgh, Bullfrog Spas are the perfect hot tubs for Pennsylvania.The Spa Sale every yinzer has been waiting for, the Pittsburgh Super Spa Sale is happening this weekend! All 2019 hot tub floor models are at clearance pricing to make room for the new 2020 models due in any month now. Stop into …Bullfrog Spas, Hot Tubs Built for Pennsylvania Pennsylvania is a diverse state with a wide variety of people and lifestyles. We also carry a full line of pool supplies and hot tub supplies. Offering Endless Pools, Swim Spas, Hot Spring hot tubs, Caldera hot tubs & Freeflow Spas.We sell thousands of hot tubs every year throughout the U.S.1 day ago Save thousands by avoiding the mark up of local dealers and buy direct. Spa Blowout sells Premium Best Buy rated hot tubs & swim spas at or below wholesale prices. Lastly, if your circulation pump is running like it should be, and your flow switch is testing as it should be, then you have a rare instance where your circuit board is misreading the information sent to it by the flow switch and your circuit board will need replaced.Hot tubs for sale pittsburgh. If you are showing any other results, then you most likely need to replace the flow switch.ĥ. If your flow switch appears visually closed, and you test across those two wires, your should be getting roughly 0 ohm's or no resistance. To test the flow switch, set your meter to ohm's. Now, if your circ pump is running and the flow switch appears physically in the closed position, then test the flow switch.Ĥ. If is not receiving voltage but it should be, then you likely have a circuit board issue.

sundance hot tub control panel

If your pump is receiving the specified voltage but is not running, then replace the circulation pump. This will tell you approximately what voltage your circulation pump should be getting. Next, check the service tag on the side of your circulation pump. First verify your spa is receiving the specified incoming voltage into the circuit board as well as out of the circuit board to the transformer. If it's completely open, and you have verified there are no water flow obstructions, then it is time to make sure your circulation pump is receiving power.ģ. kinked plumbing line, organic build up, partially clogged filter, etc). If water is properly flowing, then you should be able to see that that the paddle inside the flow switch is firmly pressed up against the vertical reed.If its fluttering, there may be a partial obstruction (i.e. Next thing to do is open your cabinet and take a look at your flow switch. While it is not a 100% guarantee this is your issue, it could be a contributing factor.Ģ.

sundance hot tub control panel

If the error goes away, then it would be a good idea to replace those filters. First thing to do is remove your filter(s). If you arent comfortable with testing electrical current, please call a local technician):ġ. So, here are the steps you want to follow to determine what is causing your issue (please note- Be safe. While that may certainly be the case, it may also not be the root cause of the issue. As people read through their owners manual, it is easy for people to quickly come to the conclusion that the first thing they need to replace is their flow switch. The flow errors FL1 and FLO are the most common error codes we get calls about.















Sundance hot tub control panel